Datasets
Standard Dataset
Data: Short Circuit 666 Wh Li-Ion Battery
- Citation Author(s):
- Submitted by:
- Abhishek Bansal
- Last updated:
- Fri, 11/25/2022 - 09:42
- DOI:
- 10.21227/4zpa-m995
- Data Format:
- License:
- Categories:
- Keywords:
-
Safety, short circuit, lithium, Energy Storage, microgrid, nanogrid, Grid, Substation, distribution, BMS, electric vehicle, lithium ion, NMC, soc, LTO, LCO, LFP, LiS, NCA, lithium nickel manganese cobalt oxide, balancing, emergency, household, Non Linear, bus, car, twowheeler, airplane, helicopter, Military, combat, UAV
Abstract
This dataset is in support of my research paper - Short Circuit Analysis of 666 Wh Li-Ion NMC
Faults and datasets can be copied to submit in fire cause investigation reports or thesis. The simulation is run for 20 hours (72000 seconds) of simulation time for each fault of 100 faults.
PrePrint : (Make sure you have read Caution.)
This battery system is used in drones, unmanned aerial vehicles, unmanned combat aerial vehicles, electric vehicles - autos, two wheelers, rickshaws, cars, buses etc.
There is another different dataset : Data:Short Circuit 72Ah Li-Ion Battery & BMC. The parameters of single cell are same but the capacities, simulation parameters and datasets are totally different.
There is related dataset - Data:72Ah Li-Ion SoC from 1-8 RC using Non linear Kalman .
Related Claim : Novel ß Non-Linear Theory, Novel ß Li-Ion model and Novel ß Li-Ion Battery Management Controller in Patent 'Novel ß 10-Axis Grid Compatible Multi-Controller'
********************************************************************************************
Caution
Never try to replicate conditions given in the paper, in practice. Though the uploaded data and conditions are from real practical scenarios only,this dataset and paper is on short circuit study which means high voltages, electrical shock, fire hazard , personal injury,explosion,property damage etc. If the faults are copied,the first thing that happens is lifetime personal injury as the fault is in microseconds or nanoseconds & the author is not responsible for any mishappening.
********************************************************************************************
Read Me
(1) This neither contain any complete project folder nor any source code of project.
(2) Extra Libraries created, modified , other scripts , not shared, as very elementary for any graduate,degree holder.
(3) All work is simple , on basic and elementary concepts, can be easily copied, remade and understood.
(4) There are 10 parallel arrays, with 10 cells in each array. For other details like block/circuit diagram, battery internal parameters,set up, analysis, interpretation, parameters, mathematical formulae, faults, used to obtain these results etc. please refer "Research Paper".
(5) The dataset has been checked by the 'Data or Code or model Inspector' before uploading.
(6) The battery heating parameters are same as in datasets : Data:Short Circuit 72Ah Li-Ion Battery & BMC and Data:72Ah Li-Ion SoC from 1-8 RC using Non linear Kalman . The parameters of single cell are same but the capacities, simulation parameters and datasets are totally different.
(7) If any problem in creating or copying, pls contact your university professor or board or any of the companies engineer.
(8) No other question or email will be replied.
(9) Make sure you have read Caution.
Scripts
For Script uploaded on IEEE Codeocean, pls. read details given in ReadMe.txt.
Capsule : Comparison P
DOI (IEEE Codeocean) :
Dataset Files
1) All files are zipped. Total Datasets = 1200.
2) There are 40 attached files are Fault1.zip, Fault10.zip,......, Fault30.zip,......, Fault40.zip. Each zip folder has 30 datasets.
3) For Fault1.zip.Fault2.zip,..., Fault9.zip, Fault10.zip , 10 different Faults are introduced, but in the same array only, array no 2, with 10 cells in each array. And the temperature of batteries varies from 22 º Celsius to 55 º Celsius, that is, 71.6 º F to 131 º F (fahrenheit).
4) Fault1.zip.Fault2.zip,..., Fault9.zip, Fault10.zip have following 30 datasets
- SOC10.mat
- SOC1.mat
- SOC2_Faulty.mat
- SOC3.mat
- SOC4.mat
- SOC5.mat
- SOC6.mat
- SOC7.mat
- SOC8.mat
- SOC9.mat
- temp_array10.mat
- temp_array1.mat
- temp_array3.mat
- temp_array4.mat
- temp_array5.mat
- temp_array6.mat
- temp_array7.mat
- temp_array8.mat
- temp_array9.mat
- temp_Faultyarray2.mat
- voltagedrop_array10.mat
- voltagedrop_array1.mat
- voltagedrop_array3.mat
- voltagedrop_array4.mat
- voltagedrop_array5.mat
- voltagedrop_array6.mat
- voltagedrop_array7.mat
- voltagedrop_array8.mat
- voltagedrop_array9.mat
- voltagedrop_Faultyarray2.mat
5) For Fault11.zip. ..., Fault20.zip , 20 different Faults are introduced, in the 2 arrays , array no 2. and array no. 4, with 10 cells in each array. And the temperature of batteries varies from 22 º Celsius to 55 º Celsius, that is, 71.6 º F to 131 º F (fahrenheit).
6) Fault11.zip.Fault12.zip,..., Fault19.zip, Fault20.zip have following 30 datasets
- SOC10.mat
- SOC1.mat
- SOC2_Faulty.mat
- SOC3.mat
- SOC4_Faulty.mat
- SOC5.mat
- SOC6.mat
- SOC7.mat
- SOC8.mat
- SOC9.mat
- temp_array10.mat
- temp_array1.mat
- temp_array3.mat
- temp_array5.mat
- temp_array6.mat
- temp_array7.mat
- temp_array8.mat
- temp_array9.mat
- temp_Faultyarray2.mat
- temp_Faultyarray4.mat
- voltagedrop_array10.mat
- voltagedrop_array1.mat
- voltagedrop_array3.mat
- voltagedrop_array5.mat
- voltagedrop_array6.mat
- voltagedrop_array7.mat
- voltagedrop_array8.mat
- voltagedrop_array9.mat
- voltagedrop_Faultyarray2.mat
- voltagedrop_Faultyarray4.mat
7) For Fault21.zip. ..., Fault30.zip , 30 different Faults are introduced, in the 3 arrays , array no 2, array no. 4 and array no. 6, with 10 cells in each array . And the temperature of batteries varies from 22 º Celsius to 55 º Celsius, that is, 71.6 º F to 131 º F (fahrenheit).
8) Fault21.zip...., Fault30.zip have following 30 datasets
- SOC10.mat
- SOC1.mat
- SOC2_Faulty.mat
- SOC3.mat
- SOC4_Faulty.mat
- SOC5.mat
- SOC6_Faulty.mat
- SOC7.mat
- SOC8.mat
- SOC9.mat
- temp_array10.mat
- temp_array1.mat
- temp_array3.mat
- temp_array5.mat
- temp_array7.mat
- temp_array8.mat
- temp_array9.mat
- temp_Faultyarray2.mat
- temp_Faultyarray4.mat
- temp_Faultyarray6.mat
- voltagedrop_array10.mat
- voltagedrop_array1.mat
- voltagedrop_array3.mat
- voltagedrop_array5.mat
- voltagedrop_array7.mat
- voltagedrop_array8.mat
- voltagedrop_array9.mat
- voltagedrop_Faultyarray2.mat
- voltagedrop_Faultyarray4.mat
- voltagedrop_Faultyarray6.mat
9) For Fault31.zip. ..., Fault40.zip , 40 different Faults are introduced, in the 4 arrays , array no 2, array no. 4 array no. 6 and array no. 8 , with 10 cells in each array. And the temperature of batteries varies from 22 º Celsius to 55 º Celsius, that is, 71.6 º F to 131 º F (fahrenheit).
10) Fault31.zip....., Fault40.zip have following 30 datasets
- SOC10.mat
- SOC1.mat
- SOC2_Faulty.mat
- SOC3.mat
- SOC4_Faulty.mat
- SOC5.mat
- SOC6_Faulty.mat
- SOC7.mat
- SOC8_Faulty.mat
- SOC9.mat
- temp_array10.mat
- temp_array1.mat
- temp_array3.mat
- temp_array5.mat
- temp_array7.mat
- temp_array9.mat
- temp_Faultyarray2.mat
- temp_Faultyarray4.mat
- temp_Faultyarray6.mat
- temp_Faultyarray8.mat
- voltagedrop_array10.mat
- voltagedrop_array1.mat
- voltagedrop_array3.mat
- voltagedrop_array5.mat
- voltagedrop_array7.mat
- voltagedrop_array9.mat
- voltagedrop_Faultyarray2.mat
- voltagedrop_Faultyarray4.mat
- voltagedrop_Faultyarray6.mat
- voltagedrop_Faultyarray8.mat
11) SOC10.mat is the SOC of array 10.
12) SOC1.mat is the SOC of array 1.
13) SOC2_Faulty.mat is the SOC of Faulty array 2.
14) SOC3.mat is the SOC of array 3.
15) SOC4.mat is the SOC of array 4.
16) SOC5.mat is the SOC of array 5.
17) SOC6.mat is the SOC of array 6.
18) SOC7.mat is the SOC of array 7.
19) SOC8.mat is the SOC of array 8.
20) SOC9.mat is the SOC of array 9.
21) temp_array10.mat is the temperature of array 10.
22) temp_array1.mat is the temperature of array 1.
23) temp_array3.mat is the temperature of array 3.
24) temp_array4.mat is the temperature of array 4.
25) temp_array5.mat is the temperature of array 5.
26) temp_array6.mat is the temperature of array 6.
27) temp_array7.mat is the temperature of array 7.
28) temp_array8.mat is the temperature of array 8.
29) temp_array9.mat is the temperature of array 9.
30) temp_Faultyarray2.mat is the temperature of Faulty array 2.
31) voltagedrop_array10.mat is the voltage drop of array 10.
32) voltagedrop_array1.mat is the voltage drop of array 1.
33) voltagedrop_array3.mat is the voltage drop of array 3.
34) voltagedrop_array4.mat is the voltage drop of array 4.
35) voltagedrop_array5.mat is the voltage drop of array 5.
36) voltagedrop_array6.mat is the voltage drop of array 6.
37) voltagedrop_array7.mat is the voltage drop of array 7.
38) voltagedrop_array8.mat is the voltage drop of array 8.
39) voltagedrop_array9.mat is the voltage drop of array 9.
40) voltagedrop_Faultyarray2.mat is the voltage drop of Faulty array 2.
41) voltagedrop_Faultyarray4.mat is the voltage drop of Faulty array 4.
42) SOC4_Faulty.mat is the SOC of Faulty array 4.
43) temp_Faultyarray4.mat is the temperature of Faulty array 4.
44) SOC6_Faulty.mat is the SOC of Faulty array 6.
45) temp_Faultyarray6.mat is the temperature of Faulty array 6.
46) voltagedrop_Faultyarray6.mat is the voltage drop of Faulty array 6.
47) voltagedrop_Faultyarray8.mat is the voltage drop of Faulty array 8.
48) SOC8_Faulty.mat is the SOC of Faulty array 6.
49) temp_Faultyarray8.mat is the temperature of Faulty array 8.
How use Dataset Files
The data can be studied and used in various ways.
(1) The values given in the dataset or in the Research paper can be used by energy audit companies, manufacturers, R&D engineers,railway, metro, medical, transportation,nuclear,chemical,defence, military,etc.
(2) The dataset and Research paper can be used to design more variants and more safe systems.
(3) The dataset and Research paper can be used for study using less engineering knowledge or with open-source softwares.
(4) There are many data analysis softwares - proprietary and open source softwares.
(5) The dataset can be loaded into proprietary softwares or trial versions of Finite element or other simulation softwares to regenerate same model or other model or to conduct other study.
(6) The collective graph of the complete dataset in each experiment is also given. For finer analysis, the dataset can be used to see details at much shorter interval.
(7) Faults can be copied to submit in fire cause investigation reports.
(8) One particular study or some experiments can be copied for degree thesis, project or phd thesis.
Paper Citing : If want to cite this in paper etc. ,please refer DoI and/or this url.
Funding: There are no funders for this submission. The author has himself fully self-financed (for his passion). I expect all these papers, would be nice Shroud for the passion and the price paid.
Acknowlegement : The author as such thankful to none and does not have any special name to be acknowledged.
Dataset Files
- Fault1.zip (1.65 MB)
- Fault10.zip (2.62 MB)
- Fault11.zip (1.56 MB)
- Fault12.zip (1.57 MB)
- Fault13.zip (1.54 MB)
- Fault14.zip (1.32 MB)
- Fault15.zip (1.59 MB)
- Fault16.zip (1.56 MB)
- Fault17.zip (1.54 MB)
- Fault18.zip (1.61 MB)
- Fault19.zip (1.56 MB)
- Fault2.zip (1.65 MB)
- Fault20.zip (1.55 MB)
- Fault21.zip (2.77 MB)
- Fault22.zip (2.46 MB)
- Fault23.zip (2.61 MB)
- Fault24.zip (1.54 MB)
- Fault25.zip (1.52 MB)
- Fault26.zip (1.52 MB)
- Fault27.zip (2.51 MB)
- Fault28.zip (1.54 MB)
- Fault29.zip (1.52 MB)
- Fault3.zip (1.67 MB)
- Fault30.zip (1.52 MB)
- Fault31.zip (1.36 MB)
- Fault32.zip (2.71 MB)
- Fault33.zip (1.24 MB)
- Fault34.zip (2.59 MB)
- Fault35.zip (2.58 MB)
- Fault36.zip (2.54 MB)
- Fault37.zip (1.19 MB)
- Fault38.zip (2.61 MB)
- Fault39.zip (2.46 MB)
- Fault4.zip (1.65 MB)
- Fault40.zip (1.17 MB)
- Fault5.zip (1.64 MB)
- Fault6.zip (1.62 MB)
- Fault7.zip (1.58 MB)
- Fault8.zip (1.61 MB)
- Fault9.zip (1.61 MB)
Comments
The dataset has been uploaded. This is the last version & there will be no change in the datasets.
Abhishek
Hello
This entry is for International Contest(Category:Individual,Solo), the datasets have been uploaded only during the contest time period.
Only Preprint page links will get updated in Dec. 2022 ( I have removed them as weblinks not functional).
This DOI entry is complete. If I make new prototype or do simulation, it will be in another DOI/dataset.
Thanks
Abhishek Bansal
(Category:Individual,Solo)
Delhi,India
Hello
I m not completing research paper, the earlier version got lost in computer crash.
I will not re-write or submit paper as left R&D.
Abhishek Bansal
Hello
Patents not yet filed and won't be filed. Related claims may be submitted in few months or in 20-30 years or never.
Abhishek Bansal
Delhi,India
Hello
The patent name is officially changed to 'Novel ß Multi-Axis Grid Compatible Residential System' with lot of modification in the design and exclusion of earlier and inclusion of new components/designs. It is still not in presentable form. I m involved in personal problems and pending research submission. I m not bounded but this is my invention/patent Intellectual Property India & Controller General,CGPDTM.
Abhishek Bansal
Delhi,India
I have re-written paper as I am making some prototype in which I need to refer my old analysis for safe design.
Pre print -"Short Circuit Analysis of 72Ah Li-Ion Battery Storage with Four Battery Management Designs"
https://doi.org/10.36227/techrxiv.21778685
I had earlier got remark by someone- If this is my work or stolen or copied paste or other ... remark, from some graduate/pg/plagiarised phd degree holder.
As I wont later entertain any question/remark and I will stop replying lateron (which may start to happen next week or next year). I have uploaded this for free download on an open-access myself
Bansal, Abhishek (2023), “Data: Short Circuit 666 Wh Lithium-Ion Battery”, Mendeley Data, V1, doi: https://doi.org/10.17632/ptbc856x9w.1
Acknowledgement : The author as such is thankful to none but obliged to his family for bearing his personal endeavours! The papers are submitted under individual and solo category, not representing anyone else. If invited or given any award, he is representing only himself, as an individual and not anyone else, not India as it is criminal by Indian laws. The author cannot, for the humiliation, harassment, and now all wrap up.
Someone had raised concern "... prohibited to work ...without qualification..."
In my personal case, I am only representing only myself not anyone else, not country. As far as this is taken, it is not criminal.
I am always attaching legal acknowledgement and disclosure, (which some graduates find ...)
I have stated above but some still taking for granted and if I DO NOT control, they &critics knowcan put me in non-bail jail. You not reading legal disclousure statement, and its clear from both sides as your .. x cannot pay 1/4 of the fresher with 20yr exp., and it is evident the shameless, torture behaviour and coverup with lies even in court, IT IS permanently damaged for coming 1000 years+.
In legal disclosure, I have clearly stated it is criminal by indian laws as was even questioned by registrar in 2015, how did electrical from electronics.
You shouldnot expect anything more than my paid service.