Power and Energy

This is the supplementary material for the paper "Spreading of Disturbances in Realistic Models of Transmission Grids: Dependence on Topology, Inertia and Heterogeneity".

Categories:
513 Views

The data provided here correspond to the TPWRS paper presenting a novel  filter design procedure to optimally split the Frequency Regulation (FR) signal between conventional and fast regulating Energy Storage System (ESS) assets, considering typical Communication Delays (CDs).  The filter is then integrated into a previously validated FR model of the Ontario Power System (OPS) including Battery and Flywheel ESSs, which is used to analyze the impact of these ESSs, CDs, and limited regulation capacity in the FR process in a real system.  The proposed methodology to split the

Categories:
423 Views

This dataset contains (1) the Simulink model of a three-phase photovoltaic power system with passive anti-islanding protections like over/under current (OUC), over/under voltage (OUV), over/under frequency (OUF), rate of change of frequency (ROCOF), and dc-link voltage and (2) the results in the voltage source converter and the point of common coupling of the photovoltaic system during islanding operation mode and detection times of analyzed anti-islanding methods.

Categories:
1892 Views

Distribution test systems with 24, 54, 86, and 136 nodes, which can be used for distribution system reliability evaluation. All these Networks are medium-voltage (MV) distribution grids.

Categories:
849 Views

This dataset was curated for outage management in electricity networks. It is based on a modification of the IEEE 24 bus reliability test system network. The modified network comprises 10 generators, 50 buses, and 40 load zones; supplying 270,000 customers. For illustrative purposes, the network is assumed to span the region between longitudes 13.2989°W and 12.9133°W and latitudes 8.1712°N and 8.4998°N. This region happens to be located in Western Sierra Leone and covers an area of approximately 681 square kilometres.

The dataset comprises:

Categories:
1312 Views

This document provides the data for the case study of the work “Enhanced Representative Time Periods for Transmission Expansion Planning Problems”.

Categories:
323 Views

These data can describe the operatioal process of ultra-supercritical once-through boiler-turbine units in a wide load range. The data can be used for establishing a dynamic mathematical model or data-driven model, as well as reproducing the paper, entitled " A dynamic nonlinear model for a wide-load range operation of ultra-supercritical once-through boiler-turbine units" in Energy journal. 

Categories:
267 Views

This dataset is in support of my research paper  'Design and Analysis of 2kW Residential PEM Fuel Cell Inverter '.

Preprint :  

Categories:
3754 Views

 This dataset is in support of my 2 research papers ' '.

Preprint :

  • Part I :  
  • Part II : 

Related Claim : Novel ß Non-Linear Theory, Novel ß Inverter and Novel ß PFC  in Patent 'Novel ß 10-Axis Grid Compatible Multi-Controller' 

   

Categories:
1759 Views

This dataset is in support of my research paper 'Comparison of ElectroMagnetic Emissions & Harmonic Analysis of 20 HP Motor Controlled by 3L NPC Inverter'.

Preprint : https://doi.org/10.36227/techrxiv.19687041.v1

This is useful for manufacturers and r&d engineers for product costing. For more information, results, conclusions on this, pls read research paper.

Categories:
4206 Views