Power and Energy
This data file provides the MATLAB code to reconfigure the distribution networks using a fast and simple two-stage heuristic approach.
- Categories:
The dataset reflects a single household (home) power profile related to the grid. Households include typical appliances, two air-to-air heat pumps, a 3-phase 18 kW through-flow water heater, 6 kW solar panels and a 2,5 kW charger for the electric car.
For five-month (April_August) in 2022, every 0.2 sec took each 3-phase voltage and current measurement, calculate power and harmonics (up to 15th) for power profile registration.
Positive value reflects energy flow from the grid to a household, and negative values are energy flow to the grid.
- Categories:
The dataset contains two industrial cases with measurement devices installed at the medium voltage bus entrance and at the target load to be identified. It can be used for the research of non-invasive load monitoring algorithms. The types of data measured include three-phase voltage, current, active power, reactive power, as well as the amplitude and phase angle of each harmonic.
- Categories:
The code synthesizes a transfer function with real poles from tabulated frequency response data. The reproducible run of this capsule will synthesize the impedance matrix of a 500-kV double-circuit overhead power transmission line and also that of a 250-kV dc submarine power cable.
- Categories:
Device fingerprinting is a technique for remote indirect identification or classification of a device of interest. This database is designated for device fingerprinting by current consumption; it includes current recordings for 22" computer displays from 40 devices - 20 Dell P2217H and 20 Dell E2214H. Two signals for each device were sampled independently and sequentially to provide independent train and test parts. Each sampled signal includes a 250-second recording at a 50kHz sampling frequency.
- Categories:
Due to the range of battery capacities in different electric vehicles (EVs), wireless power transfer (WPT) systems need to have a large variation in the output power. Since conventional systems are usually designed for a custom specification, the power and efficiency may be significantly reduced due to the need for interoperability between ground assembly and vehicle assembly with different power ratings. To address this issue this paper proposes a DC-link parallel AC-link series (DPAS) multi-inverter multi-rectifier (MIMR) architecture for high-power WPT systems.
- Categories:
This dataset aims to provide more insight into magnetic core losses at high frequency (MHz range) with superimposed DC bias in ferrites. The tested MnZn ferrite has a nominal relative permeability of 1500 (PC50) and 800 (PC200), which was tested at frequency from 500 kHz to 3 MHz. The DC bias appears to create a shift in the Steinmetz parameters, in particular the ki and β are affected the most. Higher DC bias creates higher losses gain and higher operating frequency makes the relative losses increase lower.
- Categories: