MAT
Arc faults are a significant cause of failure in photovoltaic (PV) system and can arise due to component deterioration, installation problems, rodents chewing on wires, abrasion of insulation, or other root causes. Undetected, incipient arc faults can propagate into electrical fires. Consequently, arc-fault detectors, now mandated in many jurisdictions, are essential for safe operation of PV systems.
- Categories:
This dataset contains results of the 60 GHz indoor sensing measurement campaign using a bistatic OFDM radar based on 5G-specified positioning reference signals (PRSs). The data can be used for testing end-to-end indoor millimeter-wave radio positioning as well as simultaneous localization and mapping (SLAM) algorithms, including channel parameter estimation. Beamformed PRS with dense angular sampling in transmission and reception allows efficient capture of line-of-sight (LoS) as well as multipath components.
- Categories:
Schematic diagram to illustrate the separation and identification of nonlinear flow characteristics for the proposed method. Due to a fact that steam turbines and generators have different dynamic characteristics at different operating points, the static nonlinear flow characteristic (e.g., yellow solid lines in (a)) is overwhelmed by input and output data with dynamic characteristics, such as the blue dots in (a) and their corresponding time series are shown in (b). The key to identifying the nonlinear flow characteristic is to separate it from the linear dynamic submodels at different ope
- Categories:
The dataset includes channel frequency response (CFR) data collected through an IEEE 802.11ax device for human activity recognition. This is the first dataset for Wi-Fi sensing with the IEEE 802.11ax standard which is the most updated Wi-Fi version available in commercial devices. The dataset has been collected within a single environment considering a single person as the purpose of the study was to evaluate the impact of communication parameters on the performance of sensing algorithms.
- Categories:
The complete description of the dataset can be found at: https://arxiv.org/abs/2305.03170
- Categories:
7200 .csv files, each containing a 10 kHz recording of a 1 ms lasting 100 hz sound, recorded centimeterwise in a 20 cm x 60 cm locating range on a table. 3600 files (3 at each of the 1200 different positions) are without an obstacle between the loudspeaker and the microphone, 3600 RIR recordings are affected by the changes of the object (a book). The OOLA is initially trained offline in batch mode by the first instance of the RIR recordings without the book. Then it learns online in an incremental mode how the RIR changes by the book.
- Categories:
Monitoring cell viability and proliferation in real-time provides a more comprehensive picture of the changes cells undergo during their lifecycle than can be achieved using traditional end-point assays. Our lab has developed a CMOS biosensor that monitors cell viability through high-resolution capacitance measurements of cell adhesion quality. The system consists of a 3 × 3 mm2 chip with an array of 16 sensors, on-chip digitization, and serial data output that can be interfaced with inexpensive off-the-shelf components.
- Categories:
These datasets are of the hydraulically actuated robot HyQ’s proprioceptive sensors. They include absolute and relative encoders, force and torque sensors, and MEMS-based and fibre optic-based inertial measurement units (IMUs). Additionally, a motion capture system recorded the ground truth data with millimetre accuracy. In the datasets HyQ was manually controlled to trot in place or move around the laboratory. The sequence includes: forward and backwards motion, side-to-side motion, zig-zags, yaw motion, and a mix of linear and yaw motion.
- Categories:
The file contains two arrays:
InCondSim: the initial conditions of the combustion system organized as C3H8, C2H5, CH3, O2, C3H7, HO2, H7C3, CH4, HH, H2, OO, OH, H2O, HO2, H2O2, C2H4, C3H6, C3H5, CH2O, HCO, MM, CH3O, C2H6, C2H3, C2H2, C2H, CO, CH2, CO2.
peakPWR: the peak power generated by the combustion.
- Categories: