Other

CONTENTS OF THIS FILE

  •  Data Analysis
  •  Experimental Design

Data Analysis

This folder consists of data obtained from the experiments and the materials we use for analysis. Here we provide the following documents:

01-The folder "Class diagrams"

      This folder contains class diagrams realized by participants in three experiments.

02-Code.R 

Categories:
281 Views

The dataset contains the navigation measurements obtained in the indoor experiment field. The volunteers move on the whole 4th floor of the Building D of Dong Jiu Teaching classes at Huazhong University of Science and Technology. Meanwhile, the experimental area consists of a total area of 717 m 2. These datasets were used and can be used to test and validate the radio map database updating-based localization positioning algorithm through the RSSI signals space.

Categories:
1397 Views

The dataset contains the path loss measurements obtained with a LoRa (868 MHz) transmitting radio and five receivers. The receivers move in a search area covering both outdoor and indoor areas wherein a double-slope path loss is experienced. The data can be used to test range-based localization algorithm through the received signal strength.

Categories:
494 Views

Samples for our experiment results

Categories:
92 Views

Spreadsheet use for conversion of visible light lux measurements to irradiance.

Back up for manuscript: Calculation of Visible Light Irradiance from Lux Illuminance and Relative Spectral Illuminance

Categories:
336 Views

this dataset provides the data of the paper titled "Variable-Gain Servo Matching Method for Two-axis Servo Feed System based on Joint Time-dependent Setpoints Bandwidth", including data of figures 4, 5, 8,9,10 and 11.

Categories:
53 Views

Catalogue of Government Affairs Documents of Shanghai Archives

Categories:
134 Views

In this paper, the design and fabrication of Waveguide Triplexer (WT) model in 1GHz-5GHz frequency band width, with the capability of determination of three frequency bands (first band: 1700MHz to 2200MHZ, second band: 2600MHz to 3100MHz, and third band: 3500MHZ to 4000MHz) in Band Pass Filter (BPF) structure in the form of a separate branch for each of the triplexer branches have been simulated. The purpose of this investigation is diminution of return signal losses and improvement of signal isolation and, as well, diminution of signal time delay in multiband waveguide triplexer filters.

Categories:
83 Views

A set of electrical measurements from a TiO2-based memristive device is presented. The data correspond to a  resistive switching device, with a Ag/ITO/TiO2/Ag MIM structure. The thickness of TiO2 is 50nm. 

Categories:
200 Views

Data and simulation, accompanying the publication "Insect Inspired Self-Righting Fixed-Wing Drones".

 

Categories:
176 Views

Pages