Signal Processing

This synthetic dataset or phantom consists of 3 jpg format databases, in the two-dimensional (2-D) domain, which are identified as follows:

 

DB1: Ground Truth

 

DB2: Speckle noise with zero mean and 0.005 standard deviation

 

DB3: Speckle noise with zero mean and 0.05 standard deviation

 

Categories:
110 Views

Gas monitoring plays a crucial role in our intelligent societies. Thus we build those stepwise-collected data for gas concentration modeling in dynamic setting which can boost training data collection. First column is time, you have 8 columns for different sensors, including GM402B, GM702B, GM512B, GM302B, MICS5914, MICS5914, MICS4514, and MICS4514. The remaining 3 columns is recorded as the flow rate, which the flow rate of methane and the oxygen-nitrogen mixture is read as L/min, while hydrogen is read as mL/min.

Categories:
206 Views

The experimental measurement model includes the transmitter, receiver and signal processing parts:The transmitter part includes 1 antenna, capable of transmitting signals at a frequency of 1090 MHz.The signal supplied to the transmitting antenna is generated by the FMCOMMS5 transceiver circuit.To generate the transmit signal, a Matlab program is implemented on the computer to control the FMCOMMS5 circuit through the ZC706 FPGA board.The control process is transmitted via Ethernet communication using a LAN (Local Area Network) cable.Specifically, the signal is generated in the Matlab program

Categories:
654 Views

This dataset image is based on the monthly average temperatures collected at 299 stations of the Brazilian Meteorological Temperature Dataset. Each station in the dataset image is linked to the eight nearest stations in its vicinity. Based on the data in the Brazilian temperature dataset, we draw a graph with node numbers N = 299 and K = 8. The graph is drawn with July data in the dataset, as shown in Fig.

Categories:
208 Views

The faulty joint clearance sizes in the study are taken as 0.25 mm and 0.75 mm. The nonfaulty joint clearance size is guaranteed by fine machining (within 0.04 mm). Fifty groups of vibration data are measured per operation condition(normal condition and three mechanical fault conditions). Therefore, 400 recordings of the three clearance joint faults and normal operating conditions are collected in the end.

Categories:
59 Views

Low-light images and video footage often exhibit issues due to the interplay of various parameters such as aperture, shutter speed, and ISO settings. These interactions can lead to distortions, especially in extreme lighting conditions. This distortion is primarily caused by the inverse relationship between decreasing light intensity and increasing photon noise, which gets amplified with higher sensor gain. Additionally, secondary characteristics like white balance and color effects can also be adversely affected and may require post-processing correction.

Categories:
2007 Views

The dataset contains 5G positioning measurements simulated using a MATLAB raytracer tool in realistic environments (outdoors and indoors).
Outdoor scenarios include static and dynamic users in the urban area of Città Studi, Milan, Italy, near the Politecnico di Milano - Campus Leonardo.
The indoor context is reconstructed using a LiDAR acquisition in the MADE Competence Center I4.0 located in Politecnico di Milano - Campus Durandò, Bovisa, Milan, Italy.
The datasets include:

Categories:
202 Views

The scintillator detectors are recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the radiation particles (set by operator), and (d) number of instances/sample number are estimated. Total 5: two versions of Central Limit Theorem (CLT), (3) industry preferred Pulse Width Saturation, (4) calibration based on MPPC coupled Gamma-ray detector, and (5) gross method are used.

Categories:
30 Views

A 2D Compact ultrasound computerized tomography (UCT) system is developed. Fully automatic post-processing tools involving signal and image processing are developed as well. Square of the amplitude values are used in transmission mode with natural 1.5 MHz frequency and rise time 10.4 ns and fall time 8.4 ns and duty cycle of 4.32%. The highest peak to corresponding trough values are considered as transmitting wave between transducers in direct line talk. Sensitivity analysis of methods to extract peak to the corresponding trough per transducer are discussed in this paper.

Categories:
10 Views

A non-destructive testing system requires multiple system configuration parameters during the operation process. For a given transducer, scanning frequency and number of measurements for averaging are just among those parameters. This work tests the central limit theorem to optimally set these parameters. The authors have designed a compact ultrasound computer tomography scanner from scratch just to test this criterion. It is shown that optimal frequency value changes with respect to the scanning angle for an object with a heterogeneous inner profile.

Categories:
50 Views

Pages