Abstract
*This datasheet is being updated progressively to provide more details.
This datasheet provides the phasor measurement data in actual power systems.
These PMU data were recorded during a Low Frequency Oscillation incident and a Short Circuit Incident, respectively.
These PMU data are used for the studies in wide-area control systems (WACS) and PMU data compressions.
Please cite this datasheet and the papers in your work if they help.
Email the author for detailed information. Email: thu.zhangfang@gmail.com
The related papers and works are as follows.
[1] F. Zhang, L. Cheng, X. Li, Y. Sun, W. Gao and W. Zhao, "Application of a Real-Time Data Compression and Adapted Protocol Technique for WAMS," in IEEE Transactions on Power Systems, vol. 30, no. 2, pp. 653-662, March 2015. doi: 10.1109/TPWRS.2014.2329092
URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6847242&isnumber...
[2] F. Zhang, L. Cheng, X. Li and Y. Sun, "A Prediction-Based Hierarchical Delay Compensation (PHDC) Technique Enhanced by Increment Autoregression Prediction for Wide-Area Control Systems," in IEEE Transactions on Smart Grid, vol. 11, no. 2, pp. 1253-1263, March 2020. doi: 10.1109/TSG.2019.2934113
URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8793161&isnumber...
[3] F. Zhang, L. Cheng and W. Gao, "Prediction Based Hierarchical Compensation for Delays in Wide-Area Control Systems," in IEEE Transactions on Smart Grid, vol. 9, no. 4, pp. 3897-3899, July 2018. doi: 10.1109/TSG.2017.2750405
URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8030337&isnumber...
[4] L. Cheng, X. Ji, F. Zhang, H. Huang and S. Gao, "Wavelet-based data compression for wide-area measurement data of oscillations," in Journal of Modern Power Systems and Clean Energy, vol. 6, no. 6, pp. 1128-1140, November 2018. doi: 10.1007/s40565-018-0424-2
URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9026393&isnumber...
[5] Fang Zhang, "Phasor Measurement Data Recorded During Low Frequency Oscillation and Short Circuit Incidents in Actual Power Systems", IEEE Dataport, 2020. [Online]. Available: http://dx.doi.org/10.21227/1x22-r651. Accessed: May. 18, 2020.
Refer to the documentation file for detailed information.
Dataset Files
- 2p_shortcircuit_phasor_data.mat (5.15 MB)
- LFO_phasor_data.mat (8.56 MB)
Open Access dataset files are accessible to all logged in users. Don't have a login? Create a free IEEE account. IEEE Membership is not required.
Documentation
Attachment | Size |
---|---|
Data_Instructions_LFO&2p_20200518.pdf | 2.51 MB |
Comments
Hello,
I am doing my master thesis on PQ noise analysis and this datasheet looks very related and useful. Since I do not have access to the dataset, would you please share it with me or send to ali12af@gmail.com?
Thanks in advance,
Jan
Sorry for the delayed response, this dataset is an open-access resource.