Signal Processing

The channel path data (signal strength, delay, angle of departure and angle of arrival, etc. of each path for each Tx-Rx pair) calculated by a ray-tracing model in an industrial warehouse, via Wireless InSite
https://www.remcom.com/wireless-insite-em-propagation-software

For more details, please download the scripts and .zip to access the instructions and the data files that contain the path information.

Categories:
715 Views

We focus on subjective and objective Point Cloud Quality Assessment (PCQA) in an immersive environment and study the effect of geometry and texture attributes in compression distortion. Using a Head-Mounted Display (HMD) with six degrees of freedom, we establish a subjective PCQA database named SIAT Point Cloud Quality Database (SIAT-PCQD). Our database consists of 340 distorted point clouds compressed by the MPEG point cloud encoder with the combination of 20 sequences and 17 pairs of geometry and texture quantization parameters.

Categories:
630 Views

This dataset consists of 2579 image pairs (5158 images in total) of wood veneers before and after drying. The high-resolution .png images (generally over 4000x4000) have a white background. The data has been collected from a real plywood factory. Raute Corporation is acknowledged for making this dataset public. The manufacturing process is well visualized here: https://www.youtube.com/watch?v=tjkIYCEVXko.

Categories:
1210 Views

Three raw (i.e., In-Phase and Quadrature data with a software radio, and observation files) GNSS dataset were recorded using a LabSat Version 3 inside of the West Virginia University  greenhouse and two outside recordings were also made to provide a quality reference and comparison. The outdoor location had to be an ideal location for satellite signal reception  and  the  indoor  location  was  a  greenhouse  room  where satellite visibility was limited, susceptible to attenuation, occlusion and multipath.

Categories:
676 Views

The data set is collected using Neurosky MindWave 2.0 Headset. It uses a single dry electrode placed at FP-1 position for the acquisition of EEG signals. The data is collected from Healthy Individuals and Epileptic Patients performing different Activities of Daily Living (ADLs) in an unconstraint environment. 

Categories:
1249 Views

A qualitative and quantitative extension of the chaotic models used to generate self-similar traffic with long-range dependence (LRD) is presented by means of the formulation of a model that considers the use of piecewise affine onedimensional maps. Based on the disaggregation of the temporal series generated, a valid explanation of the behavior of the values of Hurst exponent is proposed and the feasibility of their control from the parameters of the proposed model is shown.

Categories:
161 Views

We introduce a novel dataset specifically designed for the evaluation of “alarm flood classification” (AFC) methods within process plants. The growing complexity of industrial systems and the heightened demands for operational safety and efficiency underscore the critical need for advanced diagnostic tools capable of handling alarm floods—situations where numerous alarms are triggered simultaneously.

Categories:
146 Views

This is an initiative developed by FIEC-ESPOL professors. Temperature and Speed Control Lab (TSC-LAB) is an open source hardware development.

Categories:
98832 Views

A wide range of wearable sensors exist on the market for continuous physiological health monitoring. The type and scope of health data that can be gathered is a function of the sensor modality. Blumio presents a dataset of synchronized data from a reference blood pressure device along with several wearable sensor types: PPG, applanation tonometry, and the Blumio millimeter-wave radar. Data collection was conducted under set protocol with subjects seated at rest. 115 study subjects were included (age range 20-67 years), resulting in over 19 hours of data acquired.

Categories:
3149 Views

 This  dataset of 7200 channels is generated at different locations in the room area of 30x15x4 m3, where the locations are separated by 0.25m in both horizontal and vertical directions. Each AP uses 10 dBm TX power and 2D BF. In the concurrent mmWave BT scenario, all APs are operating, while in the single mmWave BT scenario, we consider a single AP fixed on the center of the room’s ceiling

 

Categories:
210 Views

Pages