Multi-Conductor Power Line Communication CTF, Impendance, and Noise

Citation Author(s):
Davide
Righini
Institute of Networked and Embedded Systems, University of Klagenfurt, Austria
Andrea M.
Tonello
Institute of Networked and Embedded Systems, University of Klagenfurt, Austria
Submitted by:
Davide Righini
Last updated:
Tue, 05/17/2022 - 22:21
DOI:
10.21227/1tjn-2v37
Data Format:
Link to Paper:
Links:
License:
4.5
2 ratings - Please login to submit your rating.

Abstract 

Several experimental measurement campaigns have been carried out to characterize Power Line Communication (PLC) noise and channel transfer functions (CTFs). This dataset contains a subset of the PLC CTFs, impedances, and noise traces measured in an in-building scenario.

The MIMO 2x2 CTFs matrices are acquired in the frequency domain, with a resolution of 74.769kHz, in the frequency range 1 - 100MHz. Noise traces, in the time domain with a duration of about 16 ms, have been acquired concurrently from the two multi-conductor ports. 

The measurements have been performed in the laboratories and offices at the Klagenfurt University (Austria). 