Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD

Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD

Citation Author(s):
O.V.
Gradov
INEPCP RAS
P.A.
Nasirov
INEPCP RAS
Submitted by:
Oleg Gradov
Last updated:
Mon, 12/24/2018 - 09:37
DOI:
10.21227/f397-db48
Data Format:
Links:
License:
Dataset Views:
88
Rating:
0
0 ratings - Please login to submit your rating.
Share / Embed Cite
Abstract: 

Printed cirquit boards with charge coupled devices for on-chip lensless microscopes may be tested not in wetherometers and under solar simulators, but also under the experimental spectroreflectometric setup based on DATACOLOR 3890 with microphotometric and RS232-port-assisted data transfer into the PC memory.

Instructions: 

The DC 3890 is a spectrophotometer for color data acquisition using reflectance measurement. For each measurement, the sample of 16 measured values ​​in the range of visible radiation (400 to 700 nanometers) compared to a reference surface in the sphere photometer. A double-beam monochromator with two holographic gratings and two diode arrays with selectively paired photodiodes ensures high accuracy and repeatability. The microprocessor-controlled evaluation unit controls the collection and processing of measurement data.

Dataset Files

You must be an IEEE Dataport Subscriber to access these files. Login or subscribe now. Sign up to be a Beta Tester and receive a coupon code for a free subscription to IEEE DataPort!

Documentation

AttachmentSize
PDF icon DATACOLOR 3890.pdf45.45 KB

Thank you for rating this dataset!

Please share additional details of your rating with the IEEE DataPort community by adding a comment.

Embed this dataset on another website

Copy and paste the HTML code below to embed your dataset:

Share via email or social media

Click the buttons below:

facebooktwittermailshare
[1] O.V. Gradov, P.A. Nasirov, "Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD", IEEE Dataport, 2018. [Online]. Available: http://dx.doi.org/10.21227/f397-db48. Accessed: Mar. 31, 2020.
@data{f397-db48-18,
doi = {10.21227/f397-db48},
url = {http://dx.doi.org/10.21227/f397-db48},
author = {O.V. Gradov; P.A. Nasirov },
publisher = {IEEE Dataport},
title = {Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD},
year = {2018} }
TY - DATA
T1 - Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD
AU - O.V. Gradov; P.A. Nasirov
PY - 2018
PB - IEEE Dataport
UR - 10.21227/f397-db48
ER -
O.V. Gradov, P.A. Nasirov. (2018). Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD. IEEE Dataport. http://dx.doi.org/10.21227/f397-db48
O.V. Gradov, P.A. Nasirov, 2018. Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD. Available at: http://dx.doi.org/10.21227/f397-db48.
O.V. Gradov, P.A. Nasirov. (2018). "Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD." Web.
1. O.V. Gradov, P.A. Nasirov. Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD [Internet]. IEEE Dataport; 2018. Available from : http://dx.doi.org/10.21227/f397-db48
O.V. Gradov, P.A. Nasirov. "Stroboscopic microspectroreflectometry of lens-less on-chip microscope PCB with CCD." doi: 10.21227/f397-db48