Power conversion

This dataset contains (1) the Simulink model of a three-phase photovoltaic power system with passive anti-islanding protections like over/under current (OUC), over/under voltage (OUV), over/under frequency (OUF), rate of change of frequency (ROCOF), and dc-link voltage and (2) the results in the voltage source converter and the point of common coupling of the photovoltaic system during islanding operation mode and detection times of analyzed anti-islanding methods.

Categories:
1782 Views

In this simulation, the DC voltage of the matrix converter is derived using a three-phase linear load as a sample. It shows that the voltage used by the three inverters and the average over the switching period are always the same. It also shows that when the load is constant, the DC current of the inverter is also constant.

Categories:
130 Views

A simulation of power conversion from three-phase to high-frequency single-phase with a matrix converter assuming a quick charger and a non-contact power supply device.

Categories:
109 Views

In this simulation, the phase difference of the signals a, b, and c in the paper is changed to 0 in 0.1 seconds from the state where the phase is 90 degrees different from the input voltage. The input current phase is the same as the above signal. Since the output voltage gradually increases, it can be seen that the DC voltage of the matrix converter increases as the phases of a, b, and c become closer to the input voltage phase. Strictly speaking, it is proportional to cosθ as described in the paper.

Categories:
106 Views

The work starts with a short overview of grid requirements for photovoltaic (PV) systems and control structures of grid-connected PV power systems. Advanced control strategies for PV power systems are presented next, to enhance the integration of this technology. The aim of this work is to investigate the response of the three-phase PV systems during symmetrical and asymmetrical grid faults.

Categories:
8541 Views

This work presents a Matlab/Simulink study on anti-islanding detection algorithms for a 100kW Grid-Connected Photovoltaic (PV) Array. The main focus is on the islanding phenomenon that occurs at the Point of Common Coupling (PCC) between Grid-Connected PV System and the rest of the electric power system (EPS) during various grid fault conditions. The Grid-Connected PV System is simulated under the conditions of islanding, and anti-islanding (AI) relay reaction times are measured through the simulation.

Categories:
2243 Views