A 20 kVrms Insulation Test of Multi-Winding Transformer

Citation Author(s):
Xin
Liu
Submitted by:
Xin Liu
Last updated:
Mon, 01/09/2023 - 21:59
DOI:
10.21227/e8zq-nv60
License:
0
0 ratings - Please login to submit your rating.

Abstract 

This is a multi-winding transformer insulation test for the auxiliary power supply of solid state transformers. The multi-winding transformer consists of two UU80 cores. 7 PCB-based MV-side windings are placed within the epoxy layer. A 50-Hz AC voltage with an RMS value of 20 kV was applied between the MV-side and LV-side of the transformer. The insulation of the transformer performed well.

Instructions: 

This is a multi-winding transformer insulation test for the auxiliary power supply of solid state transformers. The multi-winding transformer consists of two UU80 cores. 7 PCB-based MV-side windings are placed within the epoxy layer. A 50-Hz AC voltage with an RMS value of 20 kV was applied between the MV-side and LV-side of the transformer. The insulation of the transformer performed well.

Comments

good

Submitted by adhitya simanjuntak on Tue, 01/10/2023 - 04:05