uncertainty; fault detection; false alarm; missed alarm

This study is utilized for submodule open-circuit fault detection uncertainty analysis of modular multilevel converters. The dataset consists of 8 uncertainty factors and 15 system variables under four operation scenarios. The 1000 sets of uncertainty factor samples are generated randomly as initial configuration of the system. The 15 system variables are obtained by 1000 Monte Carlo simulations. We found that there are 153 residual samples exceeded the threshold of 0.8, which indicated a high false alarm rate.

Categories:
996 Views