UQfault dataset: uncertainty of model based fault detection dataset based on a multilevel converter

Citation Author(s):
Yantao
Liao
Yi
Zhang
Aalborg University
Submitted by:
Yi Zhang
Last updated:
Sat, 07/20/2024 - 17:08
DOI:
10.21227/04e7-qw72
License:
0
0 ratings - Please login to submit your rating.

Abstract 

This study is utilized for submodule open-circuit fault detection uncertainty analysis of modular multilevel converters. The dataset consists of 8 uncertainty factors and 15 system variables under four operation scenarios. The 1000 sets of uncertainty factor samples are generated randomly as initial configuration of the system. The 15 system variables are obtained by 1000 Monte Carlo simulations. We found that there are 153 residual samples exceeded the threshold of 0.8, which indicated a high false alarm rate.

The dataset is related to the article: Y. Liao, Y. Zhang, "Rethinking Model-based Fault Detection: Uncertainties, Risks, and Optimization Based on a Multilevel Converter Case Study," IEEE Transactions on Power Electronics, Accepted in 2024. 

Instructions: 

8 uncertainty factors in file of initial_Parameters

 

delta_Lp uncertainty factor of upper arm inductance     

                 upper arm inductance equal to 20mH*delta_Lp

 

delta_Ln uncertainty factor of lower arm inductance     

                 lower arm inductance equal to 20mH*delta_Ln

 

delta_Udc    uncertainty factor of dc bus voltage measurement

                    dc bus voltage equal to 20kV*delta_Udc

 

delta_uc    uncertainty factor of submodule capacitor voltage measurement

                    submodule capacitor voltage equal to 2000V*delta_uc

 

delta_ip    uncertainty factor of upper arm current measurement

                    upper arm current equal to ip*delta_ip

 

delta_in    uncertainty factor of lower arm current measurement

                    lower arm current equal to in*delta_ip

 

ig_change    uncertainty factor of power step

                    ac-side current steps from 100A to ig_change at 0.015s

 

Udc_change   uncertainty factor of dc bus voltage step

                      dc bus voltage steps from 20kV to Udc_change*2 at 0.015s 

15 system variables 

 

ip.xlsx                           upper arm current

in.xlsx                           lower arm current

ip_delay.xlsx                 upper arm current in the former control cycle

in_delay.xlsx                 lower arm current in the former control cycle

up_est.xlsx                    estimated upper arm voltages

un_est.xlsx                    estimated lower arm voltages

up_mea.xlsx                  measured upper arm voltages

un_mea.xlsx                  measured lower arm voltages

u_sum_est.xlsx              estimated sum of upper and lower arm voltages

u_sum_mea.xlsx            measured sum of upper and lower arm voltages

u_sum_est_filter.xlsx     filtered estimated sum of upper and lower arm voltages

u_sum_mea_filter.xlsx   filtered measured sum of upper and lower arm voltages

Udc.xlsx                        dc bus voltage

Residual.xlsx                 residual

Time.xlsx                       time