UQfault dataset: uncertainty of model based fault detection dataset based on a multilevel converter
- Citation Author(s):
- Submitted by:
- Yi Zhang
- Last updated:
- Sat, 07/20/2024 - 17:08
- DOI:
- 10.21227/04e7-qw72
- License:
- Categories:
- Keywords:
Abstract
This study is utilized for submodule open-circuit fault detection uncertainty analysis of modular multilevel converters. The dataset consists of 8 uncertainty factors and 15 system variables under four operation scenarios. The 1000 sets of uncertainty factor samples are generated randomly as initial configuration of the system. The 15 system variables are obtained by 1000 Monte Carlo simulations. We found that there are 153 residual samples exceeded the threshold of 0.8, which indicated a high false alarm rate.
The dataset is related to the article: Y. Liao, Y. Zhang, "Rethinking Model-based Fault Detection: Uncertainties, Risks, and Optimization Based on a Multilevel Converter Case Study," IEEE Transactions on Power Electronics, Accepted in 2024.
8 uncertainty factors in file of initial_Parameters
delta_Lp uncertainty factor of upper arm inductance
upper arm inductance equal to 20mH*delta_Lp
delta_Ln uncertainty factor of lower arm inductance
lower arm inductance equal to 20mH*delta_Ln
delta_Udc uncertainty factor of dc bus voltage measurement
dc bus voltage equal to 20kV*delta_Udc
delta_uc uncertainty factor of submodule capacitor voltage measurement
submodule capacitor voltage equal to 2000V*delta_uc
delta_ip uncertainty factor of upper arm current measurement
upper arm current equal to ip*delta_ip
delta_in uncertainty factor of lower arm current measurement
lower arm current equal to in*delta_ip
ig_change uncertainty factor of power step
ac-side current steps from 100A to ig_change at 0.015s
Udc_change uncertainty factor of dc bus voltage step
dc bus voltage steps from 20kV to Udc_change*2 at 0.015s
15 system variables
ip.xlsx upper arm current
in.xlsx lower arm current
ip_delay.xlsx upper arm current in the former control cycle
in_delay.xlsx lower arm current in the former control cycle
up_est.xlsx estimated upper arm voltages
un_est.xlsx estimated lower arm voltages
up_mea.xlsx measured upper arm voltages
un_mea.xlsx measured lower arm voltages
u_sum_est.xlsx estimated sum of upper and lower arm voltages
u_sum_mea.xlsx measured sum of upper and lower arm voltages
u_sum_est_filter.xlsx filtered estimated sum of upper and lower arm voltages
u_sum_mea_filter.xlsx filtered measured sum of upper and lower arm voltages
Udc.xlsx dc bus voltage
Residual.xlsx residual
Time.xlsx time