Temperature Data for Analysis of Indoor Thermal Comfort in a Terraced Family House with Thermal Insulation

Citation Author(s):
Hana
Charvatova
Tomas Bata University in Zlin, Czech Republic
Ales
Prochazka
University of Chemistry and Technology in Prague, Czech Republic
Martin
Zalesak
Tomas Bata University in Zlin, Czech Republic
Jan
Drapela
Czech Technical University in Prague, Czech Republic
Vladimir
Marik
Czech Technical University in Prague, Czech Republic
Submitted by:
Hana Charvatova
Last updated:
Thu, 06/01/2023 - 13:36
DOI:
10.21227/2j4z-gk80
Research Article Link:
License:
0
0 ratings - Please login to submit your rating.

Abstract 

Computer simulations are used to assess the impact of thermal insulation on the transfer of heat and moisture in the exterior walls of residential buildings. The effects of internal and external thermal insulation on a room in a terraced family house are compared using the COMSOL Multiphysics software package, evaluating the influence of the placement of expanded polystyrene thermal insulation on the distribution of heat and moisture in the external wall while monitoring the indoor air temperature during the heating and cooling regimes. The internal thermal insulation is more efficient in terms of room heating, while the external insulation is preferable in reducing the risk of the condensation water vapor within the wall. The efficiency of heating the room to 20 °C increased by 12  °C when internal thermal insulation was added to the walls, compared to heating without insulation. The maximum value of relative humidity in the critical wall section decreased by 10 % when external thermal insulation was added.

 

Implementing internal thermal insulation needs the right choice of insulation material and its installation to prevent air leakage. The results suggest that the proper selection of the placement of the thermal insulation is critical for optimizing the thermal performance and reducing moisture-related problems in residential buildings.

Instructions: 

The dataport includes:

1.The directory "TemperatureData" including:

  •  Dataset recorded by computer simulations of surface temperatures in the critical corner of the room under the assumptions that the air temperature of the interior of the neighboring house was 10 deg.C.  (TN10_DataComsolTemperature.txt), respectively 20 deg.C. (TN20_DataComsolTemperature.txt).
  •  Corresponding thermal images recorded by a thermal camera.

 2. The " HeatingRoom.mp4" graphical video abstract.