Resource data for system validation

- Citation Author(s):
-
Luca Arpa (University of Ferrara)
- Submitted by:
- Andrea Toscani
- Last updated:
- DOI:
- 10.21227/rsq0-0840
- Data Format:
- Categories:
- Keywords:
Abstract
Comparative measurements between a digital acquisition system and an analog acquisition system, namely Siemens SCADAS.
The dataset includes calibration measurements, background noise measurements, brand new radial bearing measurements. The measurements on the brand-new radial bearing were taken on a motor test bench at 15 Hz and at 25 Hz measurements.
Each file contains a mono track at fs = 48 kHz for the digital acquisition system and fs = 51.2 kHz for the analog acquisition system.
The measurements were taken using the same sensor, a top-quality laboratory-grade piezoelectric accelerometer, PCB Piezotronics 353B18, having a full-scale of +/- 500 g and 10.4 mV/g sensitivity.
Instructions:
Each file contains a mono track at fs = 48 kHz for the digital acquisition system and fs = 51.2 kHz for the analog acquisition system
If more clarification about dataset are required, please contact: daniel.pinardi@unipr.it