electrical impedance

Abstract—This study proposes a multiclass model to classify the severity of knee osteoarthritis (KOA) using bioimpedance measurements. The experimental setup considered three types of measurements using eight electrodes: global impedance with adjacent pattern, global impedance with opposite pattern, and direct impedance measurement, which were taken using an electronic device proposed by authors and based on the Analog Devices AD5933 impedance converter. The study comprised 37 participants, 25 with healthy knees and 13 with three different degrees of KOA.

Categories:
218 Views

Simulation in R of the DSP-based impedance spectrosopy measurement device with binary excitation.

Categories:
107 Views

A solenoid-operated valve with DC resistance of about 10.3 Ω was exposed to 50 % RH, its rated temperature of 80 °C, and powered at its rated voltage of 12 VDC. (Note: the valve was unrated with regards to relative humidity, RH.) Using Fourier transform infrared (FTIR) spectroscopy, the insulation material was found to be a combination of polystyrene and polyethylene terephthalate. The wire gauge was not disclosed in the valve information sheet.

Categories:
146 Views