psimsch

This dataset provides a simulation file for the Interleaved Vienna Rectifier with Pulse-Frequency Modulation (IVR-PFM) topology, developed for three-phase, three-wire applications. The simulation is designed for use with PSIM software and is configured to operate with a 220 V, 60 Hz line input voltage, delivering 3 kW of output power at 800 V. The IVR-PFM behaves as a resistive load at the input, with the equivalent resistance defined as Re = 4Lmfs, where Lm is the magnetizing inductance and fs is the switching frequency.

Categories:
97 Views

The DFT and FFT are used mainly to obtain the amplitude of a harmonic component from a periodic signal containing several harmonics. For instance, it is desired to know the 180 Hz harmonic amplitude from a signal. Then, the DFT and FFT are the best choices to do that.

Categories:
721 Views