Real name: 
Congratulations!  You have been automatically subscribed to IEEE DataPort and can access all datasets on IEEE DataPort!
First Name: 
Yong
Last Name: 
Li

Datasets & Competitions

A transformer temperature rise test was conducted using a temperature rise recorder (JIK-8/16 Temperature Recorder) under room temperature conditions. With a water flow rate of 10L/min, the input active power was 393.23kW, the input reactive power was 305.64kvar, and the input current was 744.6A. The power loss was 8.5kW, resulting in a power conversion efficiency of 97.8%.

Categories:
212 Views

In the experiments, data is collected through tests on a LIB, specifically the Panasonic NCR186500BD, which has a capacity of 3200 mAh, a voltage of 3.6 V and is used as an energy storage unit by Tesla electric vehicles. To simulate different discharge modes of an EV battery, the Dynamic Stress Test (DST), Beijing Dynamic Stress Test (BJDST), and Federal Urban Driving Schedule (FUDS) are used as test subjects. The tests are conducted at temperatures ranging from 10 °C to 45 °C in the Energy Optimization and Power Security (EOPS) Laboratory at Hunan University, China.

Categories:
40 Views