—Packaging
Our research addresses time-dependent hysteresis effects in adhesive packaged MEMS pressure sensors.
Typically calibrated inside a certain temperature and pressure range, they provide precise pressure measurements, given
that certain setting times after temperature changes are maintained. Signal errors arise when temperature changes
induce time-dependent viscoelastic relaxation in the adhesive which cannot be compensated by calibration. High precision
- Categories:
184 Views