Imbalanced retired battery data
- Citation Author(s):
- Submitted by:
- Ji Wu
- Last updated:
- Mon, 11/04/2024 - 14:36
- DOI:
- 10.21227/qxwg-f783
- License:
- Categories:
- Keywords:
Abstract
A random batch of retired batteries from real-world applications is tested as follows.
Step 1: The battery is subjected to a charging process under a 1C rate CC regimen, reaching a cut-off voltage of 3.65V.
Step 2: The battery continues to charge under a CV phase at 3.65V until the cut-off current of 0.3A is achieved.
Step 3: A relaxation period ensues, strategically introduced to stabilize the electrochemical mechanism's internal dynamics and to minimize measurement discrepancies.
Step 4: A constant current discharge is implemented within the discharging phase until the voltage reaches a cut-off threshold of 2.5V.
A random batch of retired batteries from real-world applications is tested.
Some sample data are given here. More data will be uploaded after the study is accepted for publication.
Comments
battery data