Imbalanced retired battery data

Citation Author(s):
Ji
Wu
Hefei University of Technology
Qi
Song
University of Science and Technology of China
Mingqiang
Lin
Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences
Submitted by:
Ji Wu
Last updated:
Mon, 11/04/2024 - 14:36
DOI:
10.21227/qxwg-f783
License:
17 Views
Categories:
Keywords:
0
0 ratings - Please login to submit your rating.

Abstract 

A random batch of retired batteries from real-world applications is tested as follows.

Step 1: The battery is subjected to a charging process under a 1C rate CC regimen, reaching a cut-off voltage of 3.65V.

Step 2: The battery continues to charge under a CV phase at 3.65V until the cut-off current of 0.3A is achieved.

Step 3: A relaxation period ensues, strategically introduced to stabilize the electrochemical mechanism's internal dynamics and to minimize measurement discrepancies.

Step 4: A constant current discharge is implemented within the discharging phase until the voltage reaches a cut-off threshold of 2.5V.

 

Instructions: 

A random batch of retired batteries from real-world applications is tested.