These videos analyze the phase currents of a six-phase electric drive when different control approaches are implemented. In fact three different model predictive control strategies are studied, in addition a conventional field oriented control using a carrier-based PWM technique is also tested. These videos have been obtained during the experimental validation of the manuscript "Current Harmonic Mitigation using a Multi-vector Solution for MPC in Six-phase Electric Drives".